humeral neck locking compression locking plate

3.5/4.5 mm Synthes Plate Curved LCP® J&J Medical Devices

3.5 mm and 4.5 mm Curved Locking Compression Plate (LCP ®) System The DePuy Synthes Trauma Locking Compression Plate (LCP ®) System is part of a stainless steel and titanium plate screw system that merges locking screw technology with conventional plating techniques.

Cadaveric Analysis of Proximal Humerus Locking Plate Fit

Humerus length, head diameter, and neckshaft angle were measured. Three-hole and 5-hole 3.5-mm proximal humerus locking compression plates were affixed. A digital caliper was used to measure the maximum gap distance from the plate to the bone. Development and Clinical Application of Percutaneous Objective:To simplify the usage of locking intramedullary nail; to increase the therapeutic effect and decrease the medical costs for patients. Methods:According to the proximal constitution of the humerus and the anatomic features of the medullary cavity, percutaneous compressive locking intramedullary nail was developed.Mechanical tests and clinical observation were performed.

Internal fixation of proximal humeral fractures with

Jul 16, 2008 · Locking compression plate (LPHP) is an advantageous implant in proximal humeral fractures due to angular stability, particularly in comminuted fractures and in osteoporotic bones in elderly patients, thus allowing early mobilization. Locking Plate Screw System - Suzhou Gemmed Medical China Locking Plate Screw System catalog of Upper Limb Locking Plates, Humeral Neck Locking Plates (Left And Right Type) provided by China manufacturer -

Locking plate fixation for proximal humerus fractureswhen

Oct 15, 2020 · Abstract:Displaced proximal humerus fractures, particularly in osteoporotic bone, often require open reduction and internal fixation (ORIF). Locking plate technology has enhanced our ability to treat these fractures. However, there is a high failure rate when used alone in cases with posteromedial comminution, metadiaphyseal fracture extension, and nonunions. OptiLock Proximal Humeral Plating System Surgical Proximal Humeral Plates neck or proximal shaf. Proximal humeral fractures also occur in t A non-locking screw can be used for compression of plate to bone Design Features (Continued) Step 4:The pectoralis is retracted inferiorly and medially. Patient Positioning

PRIME PubMed Operative Treatment of 2-Part Surgical

PubMed journal article:Operative Treatment of 2-Part Surgical Neck Fracture of the Humerus:Intramedullary Nail Versus Locking Compression Plate With Technical Consideration. Download Prime PubMed App to iPhone, iPad, or Android SURGICAL TECHNIQUE Proximal Humeral Fracture Plate The Integra Proximal Humeral Fracture Plate is a single component made from stainless steel (SS 316L). The non-locking compression, locking and non-locking partial thread lag screws are made from stainless steel (SS 316L). Surgical Technique As the manufacturer of this device, Integra does not practice medicine and does not recommend this or any

The Augment of the Stability in Locking Compression

The Augment of the Stability in Locking Compression Plate with Intramedullary Fibular Allograft for Proximal Humerus Fractures in Elderly People HuaChen,1 PengYin ,2 SongWang,1,3 JiantaoLi ,1 LihaiZhang,1 KamranKhan ,4 LichengZhang ,1 andPeifuTang 1 DepartmentofOrthopedics,ChinesePLAGeneralHospital,No.FuxinRoad,Beijing, China The Augment of the Stability in Locking Compression Plate

  • AbstractIntroductionMaterial and MethodsResultsDiscussionConflicts of InterestObjective. The objective of this study was to compare the clinical outcomes and complications between the locking compression plate (LCP) and LCP with fibular allograft in the treatment of patients with displaced proximal humerus fracture (PHF) in elderly people.Material and Methods. Between January 2010 and December 2013, a total of 97 elderly patients with displaced PHF were treated by LCP or LCP with fibular allograft, and finally 89 patients were included in our study. All the pT2 Proximal Humeral Nailing System Four Proximal Locking Holes strategically placed to enable locking of separate fragments of the Lesser Tuberosity, the Greater Tuberosity and the Humeral Head. The Proximal Locking Holes in the nail are threaded. Thus, the holding strength of the Locking Screws will not depend on purchase in the often poor cancellous bone.

    Two-part surgical neck fractures of the proximal part of

    Methods:Twenty-four cadaveric humeri were instrumented with use of either a titanium proximal humeral nail (PHN) or a 3.5-mm locking compression plate for the proximal part of the humerus (LCP-PH). The specimens were matched by bone mineral density and were separated into four experimental groups with six humeri in each:PHN bending, LCP-PH [Research progress in treatment of proximal humeral Feb 01, 2020 · Compared with locking plate, fibular allograft combined with locking plate can maintain better humeral neck-shaft angle and the humeral head height after operation in the treatment of proximal humeral fractures, and has better shoulder mobility and shoulder joint function, and does not increase the risk of complications.

    Locking Compression Plates for Osteoporotic Nonunions of

    Locking compression plates provide stable fixation of poor quality bone in patients with delayed union or nonunion of the humerus. Successful union and restoration of function are achieved in most patients. We no longer consider osteoporosis a contraindication to operative fixation of an ununited fracture of the humeral diaphysis.